Availability: | |
---|---|
Quantity: | |
WF
KAYAL
8536200000
Premium choice Committed to how to provide safe, convenient and reliable contactor products for you to use better. | 6 advantages Factory direct sales, excellent technology, quality assurance, let you use the peace of mind, restassured |
Detail Open the details to see the quality.The fine and beautiful details are the guarantee of a product and the intention of the user. | Scope of application Usually installed in the distribution box on the floor,computer center, telecommunications room, elevatorcontrol room, cable TV room, building automatic controlroom, fire center, industrial automatic control room, hospitaloperating room, monitoring room and distribution boxequipped with electronic medical equipment Waiting inside. |
KYWF series intelligent miniature circuit breakers have the characteristics of advanced and reasonable structure, reliable performance, high breaking capacity, and beautiful appearance. The shell material is composed of high-quality impact-resistant and high-flame retardant materials. It is suitable for indoor, AC 50Hz, rated voltage 230V, three-phase 400V, and rated current not exceeding 100A. It is mainly used for low-voltage terminal power distribution in industrial, commercial, civil buildings and infrastructure in buildings and similar places. Leakage, overload, short circuit, over-under-voltage, over-heating, and lack of equal protection can also be used for infrequent on-off operations. The leakage circuit breaker with the rated residual operating current less than 30mA can provide protection for personal electric shock.
Number of poles | 1P, 2P, 3P, 4P |
Breaking capacity | 1A-63A, 10kA |
80-100A, 6kA | |
Rated voltage | 230/400V AC |
Rated current | 1A-100A |
Residual current type | A type, AC type |
Residual current specifications | 30, 100, 300mA or adjustable |
Trip time | Standard type, time delay type, adjustable type |
Configurable leakage function | Shut down, alarm, alarm and protection |
Leakage self-test | Automatic non-trip self-check, remote and local trip self-check |
Short circuit protection | Type B, Type C, Type D |
Trip time | <0.1s |
Overcurrent protection | Thermal element + electronic |
Thermal trip | Inverse time limit |
Electronic trip | Inverse time or definite time |
Working current | Electronically adjustable |
Overvoltage protection | JB/T 12762 OUPA standard |
Overvoltage setting value | 275V |
Undervoltage setting value | 0.7Ue |
Action time | Standards compliant |
Meet the standard | Shut down, alarm, alarm and protection |
Terminal temperature rise protection | Alarm + protection |
Temperature rise alarm setting value | >50K |
Temperature rise action setting value | >60K |
Action time | 15min |
Temperature rise protection function can be configured | Shut down, alarm, alarm and protection |
Three-phase unbalance | Monitoring + alarm |
Lack of phase | Monitoring + alarm + protection |
Configurable function | Shut down, alarm, alarm and protection |
Premium choice Committed to how to provide safe, convenient and reliable contactor products for you to use better. | 6 advantages Factory direct sales, excellent technology, quality assurance, let you use the peace of mind, restassured |
Detail Open the details to see the quality.The fine and beautiful details are the guarantee of a product and the intention of the user. | Scope of application Usually installed in the distribution box on the floor,computer center, telecommunications room, elevatorcontrol room, cable TV room, building automatic controlroom, fire center, industrial automatic control room, hospitaloperating room, monitoring room and distribution boxequipped with electronic medical equipment Waiting inside. |
KYWF series intelligent miniature circuit breakers have the characteristics of advanced and reasonable structure, reliable performance, high breaking capacity, and beautiful appearance. The shell material is composed of high-quality impact-resistant and high-flame retardant materials. It is suitable for indoor, AC 50Hz, rated voltage 230V, three-phase 400V, and rated current not exceeding 100A. It is mainly used for low-voltage terminal power distribution in industrial, commercial, civil buildings and infrastructure in buildings and similar places. Leakage, overload, short circuit, over-under-voltage, over-heating, and lack of equal protection can also be used for infrequent on-off operations. The leakage circuit breaker with the rated residual operating current less than 30mA can provide protection for personal electric shock.
Number of poles | 1P, 2P, 3P, 4P |
Breaking capacity | 1A-63A, 10kA |
80-100A, 6kA | |
Rated voltage | 230/400V AC |
Rated current | 1A-100A |
Residual current type | A type, AC type |
Residual current specifications | 30, 100, 300mA or adjustable |
Trip time | Standard type, time delay type, adjustable type |
Configurable leakage function | Shut down, alarm, alarm and protection |
Leakage self-test | Automatic non-trip self-check, remote and local trip self-check |
Short circuit protection | Type B, Type C, Type D |
Trip time | <0.1s |
Overcurrent protection | Thermal element + electronic |
Thermal trip | Inverse time limit |
Electronic trip | Inverse time or definite time |
Working current | Electronically adjustable |
Overvoltage protection | JB/T 12762 OUPA standard |
Overvoltage setting value | 275V |
Undervoltage setting value | 0.7Ue |
Action time | Standards compliant |
Meet the standard | Shut down, alarm, alarm and protection |
Terminal temperature rise protection | Alarm + protection |
Temperature rise alarm setting value | >50K |
Temperature rise action setting value | >60K |
Action time | 15min |
Temperature rise protection function can be configured | Shut down, alarm, alarm and protection |
Three-phase unbalance | Monitoring + alarm |
Lack of phase | Monitoring + alarm + protection |
Configurable function | Shut down, alarm, alarm and protection |