SUV-PV
KAYAL
8536300000
SPD is used to protect all kinds of electrical equipment in the power system from lightning over-voltage, operation over-voltage, power frequency transient over-voltage impact damage to an electrical appliance The electrical circuit or communication lines because of outside interference peak current or voltage suddenly, the surge protector can in a very short time conducting shunt, so as to avoid damage to other equipment surge in the loop Installed front of inverter input and back of inverter output Installed in Parallel the spd is installed in the electric circuit with parallel, the first to play a protective role, the response time in the 25 to 50 nanosecond.
surge protector | ||||
Normal PV system voltage | 1000V | 1200V | 1500V | |
MCOV | 1170V DC | 1200V DC | 1500V DC | |
Max system discharge current | 40ka | 30ka | 30ka | |
Voltage protection level | ≤4kv | ≤4.5kv | ≤4.5kv | |
Voltage protection | ≤3.5kv | ≤4kv | ≤4kv | |
level at 5ka | ||||
Integrated Fuse | 30ka/100v dc | 30ka/1200v dc | 30ka/1500v dc | |
breaking capacity | ||||
/interrupting rating | ||||
Technology | Short-current interription overload protection | |||
Operating temperature range | -40℃ + 80℃ | |||
Normal discharge current | 12.5ka | |||
Response time | <25ns | |||
Operating state/fault indication | green(good) Red(replace) | |||
Conductor rating | Minimum | 60/75℃ 1.5mm2 /14AWG Solid/ Flexible | ||
and cross-sectionalarea | Maximum | 60/75℃ 35mm2 /2AWG Standards /25mm2/ 4AWG Flexible | ||
Mounting | 35mm din rail per EN 60175 | |||
Enclosure material | UL 94V0 thermoplactic | |||
Degree of protection | IP20 | |||
Capacity | 3 Modules, din 43880 | |||
Standards information | IEC 61643-11 Type2, IEC 61643-1 Class Ⅱ | |||
Product warranty | Five years |
SPD is used to protect all kinds of electrical equipment in the power system from lightning over-voltage, operation over-voltage, power frequency transient over-voltage impact damage to an electrical appliance The electrical circuit or communication lines because of outside interference peak current or voltage suddenly, the surge protector can in a very short time conducting shunt, so as to avoid damage to other equipment surge in the loop Installed front of inverter input and back of inverter output Installed in Parallel the spd is installed in the electric circuit with parallel, the first to play a protective role, the response time in the 25 to 50 nanosecond.
surge protector | ||||
Normal PV system voltage | 1000V | 1200V | 1500V | |
MCOV | 1170V DC | 1200V DC | 1500V DC | |
Max system discharge current | 40ka | 30ka | 30ka | |
Voltage protection level | ≤4kv | ≤4.5kv | ≤4.5kv | |
Voltage protection | ≤3.5kv | ≤4kv | ≤4kv | |
level at 5ka | ||||
Integrated Fuse | 30ka/100v dc | 30ka/1200v dc | 30ka/1500v dc | |
breaking capacity | ||||
/interrupting rating | ||||
Technology | Short-current interription overload protection | |||
Operating temperature range | -40℃ + 80℃ | |||
Normal discharge current | 12.5ka | |||
Response time | <25ns | |||
Operating state/fault indication | green(good) Red(replace) | |||
Conductor rating | Minimum | 60/75℃ 1.5mm2 /14AWG Solid/ Flexible | ||
and cross-sectionalarea | Maximum | 60/75℃ 35mm2 /2AWG Standards /25mm2/ 4AWG Flexible | ||
Mounting | 35mm din rail per EN 60175 | |||
Enclosure material | UL 94V0 thermoplactic | |||
Degree of protection | IP20 | |||
Capacity | 3 Modules, din 43880 | |||
Standards information | IEC 61643-11 Type2, IEC 61643-1 Class Ⅱ | |||
Product warranty | Five years |